Evaluation of 14 commercial HIV-1/HIV-2 antibody assays using serum panels of different geographical origin and clinical stage including a unique seroconversion panel. NLM AIDSLINE Important note: Information in this article was accurate in 1998. The state of the art may have changed since the publication date.

Click here to return to AIDSLINE main menu
DonateNow
Print this Article


Evaluation of 14 commercial HIV-1/HIV-2 antibody assays using serum panels of different geographical origin and clinical stage including a unique seroconversion panel.

J Virol Methods. 1998 Feb;70(2):139-51. Unique Identifier : AIDSLINE MED/98220879
Thorstensson R; Andersson S; Lindback S; Dias F; Mhalu F; Gaines H; Biberfeld G; Swedish Institute for Infectious Disease Control and Karolinska; Institute, Stockholm. rigmor.thorstensson@smi.ki.se


Abstract: The performance of 14 commercially available HIV-1/2 antibody assays were compared using well-characterized serum panels containing in total 1500 1800 sera. The panels included consecutive HIV-negative blood donor sera from Sweden, unselected blood donor and patient sera from Tanzania and unselected sera from outpatient clinics in Guinea-Bissau. Furthermore selected HIV-1 antibody positive sera from Sweden and Tanzania and HIV-2 antibody positive sera from Guinea-Bissau were included in the panels. The HIV-1 antibody positive sera were from individuals at various stages of HIV infection, from primary infection, to asymptomatic phase and late stage disease. 12 of the 14 assays identified correctly all HIV-1 and HIV-2 antibody positive sera. One Tanzanian HIV-1 antibody positive sample with complete banding pattern on Western blot was not detected by two of the ELISAs employing synthetic peptides. There were small differences in sensitivity between the assays when used for analysis of seroconversion panels. The most sensitive assay, Abbott IMx HIV-1/HIV-2 III Plus detected antibodies in all nine samples collected from four individuals during the first week after onset of symptoms of primary HIV-1 infection. Most of the assays became reactive during the second week after onset of symptoms and the least sensitive assays were reactive from the third week. The assays showed a high specificity ranging from 99.2 to 100% when used for analysis of Swedish blood donor sera, while most of the assays showed a significantly lower specificity, 91.9-99.6%, when used for testing African specimens.
Keywords: *HIV Antibodies/ANALYSIS *HIV-1/IMMUNOLOGY *HIV-2/IMMUNOLOGY *Reagent Kits, Diagnostic/VIROLOGYKWDhivantibodies/analysisKWDhiv-1/immunologyKWDhiv-2/immunologyKWDreagentkits,diagnostic/virology
980830
M9881109

Copyright © 1998 - National Library of Medicine. Reproduced under license with the National Library of Medicine, Bethesda, MD.

AEGiS is a 501(c)3, not-for-profit, tax-exempt, educational corporation. AEGiS is made possible through unrestricted funding from Boehringer Ingelheim, Bridgestone/Firestone Charitable Trust, Bristol-Myers Squibb Company, Elton John AIDS Foundation, Gill Foundation, the National Library of Medicine, Quest Diagnostics, Roche and Trimeris, and donations from users like you. Always watch for outdated information. This article first appeared in 1998. This material is designed to support, not replace, the relationship that exists between you and your doctor.

AEGiS presents published material, reprinted with permission and neither endorses nor opposes any material. All information contained on this website, including information relating to health conditions, products, and treatments, is for informational purposes only. It is often presented in summary or aggregate form. It is not meant to be a substitute for the advice provided by your own physician or other medical professionals. Always discuss treatment options with a doctor who specializes in treating HIV.

Copyright ©1980, 1998. AEGiS. All materials appearing on AEGiS are protected by copyright as a collective work or compilation under U.S. copyright and other laws and are the property of AEGiS, or the party credited as the provider of the content. .